Mfg Part Number: 561CC0KBA102ES1R5C
NSN : 5910-01-319-2985
NIIN : 013192985
CAGE Code : 60705
Manufacturer: Ceramite Corp
Item Name : Capacitor Fixed Ceramic Dielectr
FSC : FSC 5910 Capacitors
If you’re in need of NSN parts, look no further than NSN Orbit. Owned and operated by ASAP Semiconductor, we have access to an unparalleled inventory of parts and components for the aerospace, civil aviation, defense, electronics, and industrial markets. This includes parts such as Capacitor Fixed Ceramic Dielectr from Ceramite Corp, as well as part numbers like 561CC0KBA102ES1R5C and many more. NSN Orbit has more than two billion new and obsolete parts readily available with short lead times and competitive prices, and as we are an AS9120B, ISO 9001:2015, and FAA AC 00-56B accredited business, and the only independent distributor with a strict No China Sourcing Pledge, each part we sell is fully traceable or comes directly from the manufacturer.
Our website offers an array of parametric search capabilities that allow our customers to search for parts through a number of filters, one of which is the National Stock Number, or NSN. A National Stock Number is an identifier applied to any item of supply that is repeatedly procured, stocked, stored, issued, and used throughout the federal supply system. NSN Orbit has a broad selection of NSN parts such as 5910013192985 from manufacturers like Ceramite Corp. To begin the purchasing process immediately, submit an RFQ today for part number 561CC0KBA102ES1R5C.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5910-01-319-2985 Item Description: Capacitor Fixed Ceramic Dielectr | 5910 | 013192985 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
561cc0kba102es1r5c | 5 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
AAQL | BODY STYLE | W/O MTG FACILITIES, RADIAL TERMINALS |
ABJT | TERMINAL LENGTH | 0.200 INCHES MINIMUM |
AEBS | CENTER TO CENTER DISTANCE BETWEEN TERMINALS PARALLEL TO DIAMETER | 0.230 INCHES MINIMUM AND 0.270 INCHES MAXIMUM |
AEBZ | SCHEMATIC DIAGRAM DESIGNATOR | NO COMMON OR GROUNDED ELECTRODE(S) |
AGAV | END ITEM IDENTIFICATION | 6625-00-422-3241 VOLTMETER,DIGITAL |
CWJK | CASE MATERIAL | PLASTIC |
CWSG | TERMINAL SURFACE TREATMENT | SOLDER |
TTQY | TERMINAL TYPE AND QUANTITY | 2 UNINSULATED WIRE LEAD |
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABPM | BODY DIAMETER | 0.360 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 0.234 INCHES MAXIMUM |
AEBT | TERMINAL DIAMETER | 0.025 INCHES NOMINAL |
CQBQ | CAPACITANCE VALUE PER SECTION | 1.500 PICOFARADS SINGLE SECTION |
CQJJ | NONDERATED OPERATING TEMP | 55.0 DEG CELSIUS MINIMUM AND 85.0 DEG CELSIUS MAXIMUM |
CQLZ | TEMP COEFFICIENT OF CAPACITANCE PER SECTION IN PPM PER DEG CELSIUS | 0.0 SINGLE SECTION |
CQWM | NONDERATED CONTINUOUS VOLTAGE RATING AND TYPE PER SECTION | 1000.0 DC SINGLE SECTION |
CRHD | TOLERANCE OF TEMP COEFFICIENT PER SECTION IN PPM PER DEG CELSIUS | -250.0/+250.0 SINGLE SECTION |
CRTP | TOLERANCE RANGE PER SECTION | -0.25/+0.25 PICOFARADS SINGLE SECTION |
CWPK | INSULATION RESISTANCE AT REFERENCE TEMP | 10000.0 MEGOHMS |
CWPM | DISSIPATION FACTOR AT REFERENCE TEMP IN PERCENT | 2.000 |